Need help selecting hardware for a project?
Browse our guides below, then reach out for recommendations based on your glass thickness, layout, and application.
Latest Blogs
Most glass railing problems are decided before anyone lifts a panel. Good installation planning confirms five things up front: the substrate and how the system anchors to it, the setting out and tolerances, the glass and hardware spec, the engineering and code sign-off, and the sequence of work. Get these right and the install is […]
Glass railing thickness is driven by the system type, the guard height, the span between supports, the load the guard must resist, and whether the glass is tempered or laminated. There is no single correct thickness, because a base-supported frameless guard and a clamped panel with a top rail carry load differently. A common minimum […]
In code language a glass railing is a “guard,” and the requirements cover four things: the guard height, the size of openings, the structural loads it must resist, and the type of glass allowed. In Canada the National Building Code (NBC) is a model code that each province adopts and modifies on its own schedule, […]